Study on the equivalent pulse current injection waveform of SGEMP
Author:
Affiliation:

National Key Laboratory of Intense Pulsed Radiation Simulation and Effect,Northwest Institute of Nuclear Technology, Xi′an,Shaanxi 710024,China

Funding:

Ethical statement:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
    Abstract:

    The determination method of Pulse Current Injection(PCI) waveform parameters of System Generated Electromagnetic Pulse(SGEMP) is studied by using electromagnetic norm. When the load is high and low resistance respectively, the typical response waveform of SGEMP is double exponential waveform and Gaussian waveform. Considering the difference between the rise time, the peak value, the energy and the charge carried by the equivalent waveform and the response waveform, the equivalent waveform parameters of pulse current injection are studied. The results show that the square wave equivalent waveform can simulate the response waveform according to the characteristics of the response waveform and electronic system. Therefore, it is possible to use electromagnetic norm to parameterize the equivalence of SGEMP response waveform, and the equivalent waveform can be easily generated in laboratory, which provides a new way for the study of SGEMP by the current injection method.

    Reference
    Related
    Cited by
Get Citation

李进玺,吴伟,程引会,王一雄,赵墨,郭景海. SGEMP等效脉冲电流注入波形研究[J]. Journal of Terahertz Science and Electronic Information Technology ,2023,21(10):1239~1243