A broadband millimeter wave amplitude detection method
Author:
Affiliation:

Chengdu Seekon Microwave Communication Co.,Ltd.,The 29th Research Institute of the CETC,Chengdu Sichuan 610091,China

Funding:

Ethical statement:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
    Abstract:

    With the rapid development of electronic information technology in recent years, millimeter waves have been increasingly applied to communication, imaging, electronic countermeasures, radar, and guidance systems. In response to the limitation that domestic Successive Detector Logarithmic Video Amplifiers(SDLVAs) have difficulty in continuous detection in the millimeter wave band, a detection circuit design scheme based on the down-conversion mode is proposed. By using an internal local oscillator to down-convert the 26~38 GHz RF signal to 3~15 GHz, and then using a domestic SDLVA chip to perform continuous detection logarithmic video amplification on 3~15 GHz, the product design and testing show that this millimeter wave broadband detection can achieve a sensitivity of -57 dBm and a large dynamic detection output of 37 dB in a wide temperature range of -55~+70 ℃. The product features full domestication and miniaturization, giving it a significant advantage in broadband millimeter wave detection.

    Reference
    Related
    Cited by
Get Citation

赵丽萍,杨秀强,庞玉会,张冰,辜霄,杨先国,吴昊.一种宽带毫米波幅度检测方法[J]. Journal of Terahertz Science and Electronic Information Technology ,2025,23(1):24~28

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
History
  • Received:October 10,2024
  • Revised:December 05,2024
  • Adopted:
  • Online: February 17,2025
  • Published: